LED Operation Theatre Lights

Features:

  • Auto Focus
  • Beam Formation
  • Laminar air flow compatibility and Compact design
  • Shadow Free illumination
  • Suturing Light for convenient post-operative procedure
  • Multi Lens System

 

Select the chosen product and click Add To Quote

 

This product is currently out of stock and unavailable.

SKU: N/A Category:

Features: 

Auto Focus 

Due to high Focus Co-efficient of LEDs, the beam formation takes place at exactly 1 meter distance. Hence manual adjustment is eliminated; focus can be attained from any convenient angle by simple adjustment of distance of dome from site.


Beam Formation

LED light produces high light intensity across the full illuminate area avoiding the variable contrast lighting and distractions, and offers uniform Vision for working area. Each Reflector generates homogeneous lighting for surface. This creates an ideal depth of illumination, enabling the operator to work without the need to make the readjustments. Traditional Operating Theater lights create a high light intensity by squashing the light flux into the middle of the beam, creating a “hot Spot”. This high contrast ‘hot spot’ gives a very bright centre, leaving the rest of the field relatively dim in-comparison.


Laminar air flow compatibility and Compact design

The open design of the LED lights reduces the Surface area that impedes the flow of air from the air supply ceilings, resulting in a less turbulent flow underneath the light and thus controlling the contamination in the operating room. The shape of  DOME assures the visual comfort and is particularly suitable for Laminar Flows. Lastly its compact design makes the  LED light specifically small, flat and streamlined which in turn gives it s distinctive and justifiably futuristic appearance.


Shadow Free illumination

Shadows exist in surgery, created by surgeon position, surgical team movement, equipment or the depth of a wound. The key is to minimize shadows so a surgeon always has the clearest possible view of the surgical site. LED light insures the relation between light body and light field diameter to perform an optimum illumination of the OT field in terms of area and depth. The reflectors are designed to construct a number of light beams to dissolve the shadows.


Suturing Light for convenient post-operative procedure

When the lights are turned off, a low intensity radiant beam is emitted so that suturing process can be carried out in great comfort and without time delay.


Multi Lens System

Good Visibility and the homogeneous illumination at the surgical site are the key elements during the operation. Therefore LED has design its Multi-lens system based on the individual optical lens principle. Since each LED’s has its own convergent lens, each creates its own light field. It distributes the emitted light volume uniformly in the operating room.


Standard Series

Configuration

                 Nova LED F + F                                        Nova LED Me + Me

               Nova LED – F + Me                                  Nova LED – Me

                 Nova LED – F                                        Nova LED – Me – M

               Nova LED – F – M                                      Nova LED – Ex


Specification

Standard Series – Full DomeStandard Series – Medium DomeStandard Series – Examination Dome
Technical DataNova LED – FNova LED – MeNova LED – Ex
Reflector System431
Illumination Intensity140000 Lux.90000 Lux.40000 Lux.
LED Service Life50000 Hours.50000 Hours.50000 Hours.
Colour Temperature5500 K.5500 K.5500 K.
Colour Rendering Index93 Ra93 Ra93 Ra
Temperature increase< 2 ° C< 2 ° C< 2 ° C
in Surgeon’s head area
Index Light Spot200 – 250 mm200 – 250 mm200 – 250 mm
Brightness AdjustmentNearly 0%- 100% Nearly 0%- 100% Nearly 0%- 100% 
From Panel or Remote ControlFrom Panel or Remote Control.0From Panel or Remote Control.
Power230 VAC/ 50/60 Hz.230 VAC/ 50/60 Hz.230 VAC/ 50/60 Hz.

Eco Series

Configuration

                 Eco Line Twin                                          Eco Line

                 Eco Line – M                                             Eco Line – Ex


Specification

EcoLine SeriesEcoLine Series – Examination
Technical DataEco LineEco Line – Ex
Reflector System41
Illumination Intensity100000 Lux.35000 Lux.
LED Service Life40000 Hours40000 Hours
Colour Temperature5200 K.5200 K.
Colour Rendering Index90 Ra.90 Ra.
Temperature increase< 2 ° C< 2 ° C
in Surgeon’s head area
Index Light Spot220 – 280 mm220 – 280 mm
Brightness AdjustmentNearly 0%- 100% From PanelNearly 0%- 100% From Panel
Power230 VAC/ 50/60 Hz.230 VAC/ 50/60 Hz.

Colour Series

Configuration

                    VariCol Twin                                          VariCol – M

                   VariCol


Specification

Colour Series
Technical DataVari Col
Reflector System4
Illumination Intensity140000 Lux.
LED Service Life50000 Hours
Colour Temperature3800 K. – 5600 K. Variable
Colour Rendering IndexVariable
Temperature increase in Surgeon’s head area< 2 ° C
Index Light Spot200 – 250 mm
Brightness AdjustmentNearly 20%- 100% From Panel or Remote Control.

Advantages of Colour Variable Temperature

  • The colour temperature can be varied in multiple steps from 3800 K to 6800 K in steps of 200 K.
  • A very wide range of possible 20 options is provided.
  • Light with a higher colour temperature improves the ability to concentrate, which allows the surgeons to have optimum visual conditions depending on the extent of perfusion of the surgical sites.
  • A better contrast can be achieved by changing the light colour temperature in accordance with the tissue type and the structure of the OT Light Field.

Difference Between Standard Series & Eco Series

Difference PointsStandard SeriesEco Series
Lux IntensityStandard Series has following Lux Intensity :

  a] 140000 Lux for Full Dome.

  b] 90000 Lux for Medium Dome.

  c] 40000 Lux for Examination.

Eco Series has following Lux Intensity :

  a] 100000 Lux for the Full Dome.

  b] 35000 Lux for Examination.

LED Service Life50000 Hours.40000 Hours.
Brightness AdjustmentIn Standard Series intensity can be adjusted form the   Control Panel and Remote Control.Eco Series Intensity can be adjusted with the Control Panel   only.
Control PanelPush Button is used for increasing and decreasing the  illumination. Brightness of Light is shown in percentage   format on display which is on control panel which vary from   5% to 100% Knob placed near the center of the control panel is used for   increasing or decreasing the illumination.
Index Light Spot200 – 250 mm. 220 – 280 mm
Colour Rendering Index93 Ra 90 Ra.
Colour Temperature5200 K. 5500 K.
OptionsCombinations available in Standard Series are from Full   Dome, Medium Dome and Examination Dome.Combinations available in Eco Series are from Full Dome   and Examination Dome.
Warranty Terms3 Years on LED.2 Years on LED.

 

LED

Colour Series, Eco Series, Standard Series

Reviews

There are no reviews yet.

Be the first to review “LED Operation Theatre Lights”

Your email address will not be published. Required fields are marked *